首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   118篇
  免费   1篇
  国内免费   8篇
安全科学   10篇
废物处理   10篇
环保管理   11篇
综合类   19篇
基础理论   25篇
污染及防治   39篇
评价与监测   11篇
社会与环境   2篇
  2022年   3篇
  2021年   5篇
  2019年   4篇
  2018年   10篇
  2017年   7篇
  2016年   6篇
  2014年   4篇
  2013年   19篇
  2012年   6篇
  2011年   10篇
  2010年   6篇
  2009年   11篇
  2008年   11篇
  2007年   6篇
  2006年   3篇
  2005年   4篇
  2004年   4篇
  2003年   1篇
  2002年   2篇
  2001年   4篇
  2000年   1篇
排序方式: 共有127条查询结果,搜索用时 31 毫秒
11.
Abstract

Screening of poultry flocks for foodborne pathogen Salmonella contamination is critical for Salmonella control in preharvest stages of poultry production. In this study, two sampling methods (litter and air filter) were compared for detection of S. typhimurium from experimentally infected chicks some of which had received either a probiotic competitive exclusion culture or transfer of cecal contents from salmonellae‐free adult birds. At 4, 9, and 11 days after inoculation, S. typhimurium samples were enumerated by selective plating. For both types of sampling, the control birds yielded the greatest levels of environmental contamination followed by the samples from the probiotic inoculated birds with the birds receiving the cecal transfer culture having the lowest levels of contamination. Although the two sampling methods responded in a similar fashion, detection sensitivity needs to be increased for air filter sampling.  相似文献   
12.
Due to high usage of tetracycline antibiotics, concerns have been raised about their environmental fate. In this study, potential changes in the pseudo-first-order hydrolysis rate constants for three tetracyclines, tetracycline (TC), oxytetracycline (OTC) and chlortetracycline (CTC), were evaluated by measuring the rate constants in batch and column leaching experiments. The first-order hydrolysis rate constants were measured at pH 5, 7, and 9 using batch tests. The values were highest at pH 7 for all three tetracyclines (0.0030 ± 0.0004, 0.0042 ± 0.0001, and 0.0323 ± 0.0003 h(-1) for TC, OTC, and CTC, respectively), indicating relatively short environmental half-lives of tetracyclines. Interestingly, it was found that the rates of degradation of the parent tetracyclines were much faster when silica sand was present in a batch solution or when the solution was passed through a silica column. For example, the ratios of the first-order degradation rate constants obtained in the column experiments to those in batch experiments were 13.2, 2.1, and 2.0 for TC, OTC, and CTC at a volumetric flow rate of 0.08 mL h(-1), with an observed tendency for this ratio to increase with an increased flow rate. This indicates that the silica surface may serve as a catalyst for hydrolysis and that the actual environmental half-lives of tetracycline antibiotics could be shorter than those estimated from laboratory hydrolysis rate constants using the standard batch protocol. Furthermore, the toxicity of the column effluent containing hydrolysis metabolites was assessed using bioluminescence inhibition in Vibrio fischeri. It was estimated that the toxicity of the metabolites of CTC was lower than that of their parent compound, whereas the toxicity of metabolites of TC and OTC was as high as or higher than that of their parent compounds.  相似文献   
13.
This article investigates the impact of ISO 14001 certification on the compliance with environmental regulations by Korean companies. The impact of ISO 14001 certification on the industry was studied through a questionnaire survey and the compliance of environmental regulations were investigated using government-released data. The motivation for an environment management system was a result of the current international situation and the need to maintain fair competition. ISO 14001 certification has been recognized as an essential strategy for industrial competition and to improve company/product recognition. The certified and non-certified companies' environmental regulation violation (ERV) rates were 3.5% and 11.6%, respectively, in 1997. In 1998, the ERV rate had an eight-time difference with 1.0% and 8.5% for certified and non-certified companies, respectively. Annual regulation violation rates were reduced from 3.5% in 1997 to 1.0% in 1998 with certified companies and from 11.6% in 1997 to 8.5% in 1998 with their non-certified counterparts, respectively. ISO 14001 certified companies showed more improvement than non-certified companies in regards to environmental performance.  相似文献   
14.
Soil acidification is one of the rising land degradation issues facing world agriculture. The risk of acidification is currently being assessed as part of agriculture productivity and sustainable theme. This study was conducted to produce a new vermicomposting cast as a recycling resource derived from municipal sewage sludge and waste oyster shell. The earthworm, Eisenia Andrei, was fed under different conditions. The most suitable mixture was 77:23 w/w% of sewage sludge and waste oyster shell. Powdered oyster shell (POS) sludge blend provided a stable pH, due to its buffering capacity during vermiculture because of the Ca2+ and OH? release effect. The vermicast products fulfilled the cast standards of Korea Ministry of Environment for all the parameters such as moisture content, pH, salinity, organic carbon, TKN, Phosphate, and heavy metals. Slowly released organic matter when added to soil improves the capacity of the soil to hold nutrients for plants, improve soil aeration for roots, and improves soil drainage. This product will be an addition to already-commercialized sludge vermicast as a higher value product.  相似文献   
15.
This study provides biodegradability of organics in leachate according to their molecular mass distributions (<0.5, 0.5 to 1, 1 to 3, 10, and >10 KDa). Organics with molecular mass values lower than 0.5 KDa were the predominant species in the raw leachate filtrate, and the aerated lagoon process was very effective in treating these highly biodegradable organics; the Fenton's oxidation process was very effective in treating not-so-biodegradable organics with molecular mass values higher than 0.5 KDa, but a portion of these organics were converted into organics <0.5 KDa after Fenton's oxidation. An oxygen uptake measurement using a respirometer was more sensitive than a conventional biochemical oxygen demand measurement to evaluate bioactivities, especially when bioactivities were low.  相似文献   
16.
This study is aimed at exploring the characteristics of fatal occupational injuries in Korea’s construction industry and comparing the causes in various occupations within that industry. There were 10,276 fatal occupational injury victims in Korea over 8 years (1997–2004). The mortality risk due to injuries in construction and non-construction industries was calculated, and their causes were compared. The number of victims of fatal occupational injuries in the construction industry was 4333 (42.2% of the total fatal occupational injuries), and the 1 year mortality risk was higher (23.7/100,000 persons) than in non-construction industries (10.4). Falling was the most frequent (52.7%) cause of fatal injuries. In addition, deaths due to structural collapse and electric shock were significantly higher than in other industries. When the distribution of the causal factors in various occupations within the construction industry was investigated, some factors appeared more frequently in certain occupations than in others. As the construction industry encompasses a large proportion of occupational injuries, a reduction in this field alone will substantially contribute to an overall reduction of occupational injuries in Korea. Further research for effective prevention is needed.  相似文献   
17.
18.
An electrochemical COD (chemical oxygen demand) sensor using an electrode-surface grinding unit was investigated. The electrolyzing (oxidizing) action of copper on an organic species was used as the basis of the COD measuring sensor. Using a simple three-electrode cell and a surface grinding unit, the organic species is activated by the catalytic action of copper and oxidized at a working electrode, poised at a positive potential. When synthetic wastewater was fed into the system, the measured Coulombic yields were found to be dependent on the COD of the synthetic wastewater. A linear correlation between the Coulombic yields and the COD of the synthetic wastewater was established (10-1000 mg L(-1)) when the electrode-surface grinding procedure was activated briefly at 8 h intervals. When various kinds of wastewater samples obtained from various sewage treatment plants were measured, linear correlations (r(2)> or = 0.92) between the measured EOD (electrochemical oxygen demand) value and COD of the samples were observed. At a practical wastewater treatment plant, the measurement system was successfully operated with high accuracy and good stability over 3 months. These experimental results show that the application of the measurement system would be a rapid and practical method for the determination of COD in water industries.  相似文献   
19.
This study investigated the influence of Indian mustard (Brassica juncea) root exudation on soil solution properties (pH, dissolved organic carbon (DOC), metal solubility) in the rhizosphere using a rhizobox. Measurement was conducted following the cultivation of Indian mustard in the rhizobox filled four di erent types of heavy metal contaminated soils (two alkaline soils and two acidic soils). The growth of Indian mustard resulted in a significant increase (by 0.6 pH units) in rhizosphere soil solution pH of acidic soils and only a slight increase (< 0.1 pH units) in alkaline soils. Furthermore, the DOC concentration increased by 17–156 mg/L in the rhizosphere regardless of soil type and the extent of contamination, demonstrating the exudation of DOC from root. Ion chromatographic determination showed a marked increase in the total dissolved organic acids (OAs) in rhizosphere. While root exudates were observed in all soils, the amount of DOC and OAs in soil solution varied considerably amongst di erent soils, resulting in significant changes to soil solution metals in the rhizosphere. For example, the soil solution Cd, Cu, Pb, and Zn concentrations increased in the rhizosphere of alkaline soils compared to bulk soil following plant cultivation. In contrast, the soluble concentrations of Cd, Pb, and Zn in acidic soils decreased in rhizosphere soil when compared to bulk soils. Besides the influence of pH and DOC on metal solubility, the increase of heavy metal concentration having high stability constant such as Cu and Pb resulted in a release of Cd and Zn from solid phase to liquid phase.  相似文献   
20.
Given many potential obstacles, what types of strategic plans and measures for climate protection and/or energy sustainability are more likely than others to be adopted by cities? What are the key internal and external obstacles to adopting and implementing these plans and measures? Based on data obtained from a survey conducted from 2010 to 2011 and other sources, this paper develops a framework derived from political contracting theory and strategic orientation literature to examine how public management obstacles, socio-economic factors, and political factors influence a city's likelihood of having strategic energy sustainability plans and measures in place. Moreover, this paper finds that many California cities remain reluctant to require residents and businesses to comply with more challenging sustainability measures, such as smart-growth land-use practices, and that those cities with a strategic energy sustainability plan already in place tend to be more willing to adopt smart-growth land-use measures.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号